Type of Premises |
Type of Equipment |
User Checks Note |
Class 1 |
Class 2 |
|
Formal Visual Inspection Note |
Combined Inspection And Testing Note |
Formal Visual Inspection Note |
Combined Inspection And Testing Note |
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
|
1 |
Construction Sites 110 V Equipment |
S
IT
M
P
H |
None
None
Weekly
Weekly
Weekly |
1 Month
1 Month
1 Month
1 Month
1 Month |
3 Months
3 Months
3 Months
3 Months
3 Months |
1 Month
1 Month
1 Month
1 Month
1 Month |
3 Months
3 Months
3 Months
3 Months
3 Months |
|
2 |
Industrial Including Commercial Kitchens |
S
IT
M
P
H |
Weekly
Weekly
Before Use
Before Use
Before Use |
None
None
1 Month
1 Month
1 Month |
12 Months
12 Months
12 Months
6 Months
6 Months |
None
None
3 Month
3 Month
3 Month |
12 Months
12 Months
12 Months
6 Months
6 Months |
|
3 |
Equipment Used by the Public |
S
IT
M
P
H |
Note +
Note +
Note +
Note +
Note + |
Monthly
Monthly
Weekly
Weekly
Weekly |
12 Months
12 Months
6 Months
6 Months
6 Months |
3 Months
3 Months
1 Month
1 Month
1 Month |
12 Months
12 Months
12 Months
12 Months
12 Months |
|
4 |
Schools |
S
IT
M
P
H |
Weekly +
Weekly +
Weekly +
Weekly +
Before Use |
None
None
4 Months
4 Months
4 Months |
12 Months
12 Months
12 Months
12 Months
12 Months |
12 Months
12 Months
4 Months
4 Months
4 Months |
48 Months
48 Months
48 Months
48 Months
48 Months |
|
5 |
Hotels |
S
IT
M
P
H |
None
None
Weekly
Weekly
Before Use |
24 Months
24 Months
12 Months
12 Months
6 Months |
48 Months
48 Months
24 Months
24 Months
12 Months |
24 Months
24 Months
24 Months
24 Months
12 Months |
48 Months
48 Months
24 Months
24 Months
24 Months |
|
6 |
Offices and Shops |
S
IT
M
P
H |
None
None
Weekly
Weekly
Before Use |
24 Months
24 Months
12 Months
12 Months
6 Months |
48 Months
48 Months
24 Months
24 Months
12 Months |
24 Months
24 Months
12 Months
12 Months
12 Months |
48 Months
48 Months
24 Months
24 Months
24 Months |